详细参数
- 品牌
- Honeywell霍尼韦尔
- 规格型号
- XNX-AMSE-NNNNN
- 编号
- 齐全
- 计量单位
- 1个
- 付款方式
- 先付部分货款
- 参考价格
- 1
- 价格单位
- 人民币
- 供货量
- 不限
- 说明书,报价手册及驱动
- 暂无相关下载
- 其他资料下载
- 暂无相关下载
商品详情
Honeywell霍尼韦尔气体探测器XNX通用侦测发报器 上海宛畅XNX-AMSE-NNNNN XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies. It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed. XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART® terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance. 1. XNX Universal Transmitter- Flammable Standard Temperature with MPD sensor XNX Universal transmitter for the Multi - Purpose Detector (MPD) sensor for flammable gases. 1.1. INSTRUMENT XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL XNX-AMAV-NNCB1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-AMAV-NHCB1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-AMAV-RNCB1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-AMAV-RHCB1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-AMAV-MNCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-AMAV-MHCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-AMAV-NNCB2 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-101%LEL XNX-AMAV-NHCB2 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-101%LEL XNX Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor 0-100%LEL XNX-AMSV-NNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-NHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-RNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-RHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-MNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-MHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-FNCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL. XNX-AMSV-FHCB1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL XNX-AMAV-NNIF1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-NHIF1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-RNIF1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-RHIF1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-MNIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-MHIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-FNIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-AMAV-FHIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL XNX-AMSV-NNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR flammable (propane) sensor 0-100%LEL. XNX-AMSV-NHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX-AMSV-RNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL. XNX-AMSV-RHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX-AMSV-MNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL. XNX-AMSV-MHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX-AMSV-FNIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL. XNX-AMSV-FHIF1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). XNX-AMAV-NNIV1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-NHIV1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-RNIV1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-RHIV1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-MNIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-MHIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-FNIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-AMAV-FHIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). XNX-AMSV-NNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-AMSV-NHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-AMSV-RNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-AMSV-RHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-AMSV-MNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-AMSV-MHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-AMSV-FNIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V. XNX-AMSV-FHIV1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V. XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V. XNX-AMAV-NNIC1 XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-NHIC1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-RNIC1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-RHIC1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-MNIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-MHIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-FNIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-AMAV-FHIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V. XNX-AMSV-NNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-NHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-RNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-RHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-MNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-MHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-FNIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V. XNX-AMSV-FHIC1 XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL XNX-UTAV-NNCB1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-NHCB1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-RNCB1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-RHCB1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-MNCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-MHCB1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-FNCB1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX-UTAV-FHCB1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL XNX-UTSV-NNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-NHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-RNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-RHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-MNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-MHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-FNCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL. XNX-UTSV-FHCB1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL XNX-UTAV-NNIF1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-NHIF1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-RNIF1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-RHIF1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-MNIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-MHIF1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-FNIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX-UTAV-FHIF1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL XNX-UTSV-NNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR flammable sensor 0-100%LEL. XNX-UTSV-NHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX-UTSV-RNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL. XNX-UTSV-RHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX-UTSV-MNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL. XNX-UTSV-MHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX-UTSV-FNIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL. XNX -UTSV-FHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). XNX-UTAV-NNIV1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-NHIV1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-RNIV1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-RHIV1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-MNIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-MHIV1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-FNIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX-UTAV-FHIV1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). XNX-UTSV-NNIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-UTSV-NHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-UTSV-RNIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-UTSV-RHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-UTSV-MNIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-UTSV-MHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). XNX-UTSV-FNIV1 XNX transmitter, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V. XNX-UTSV-FHIV1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V. XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V. XNX-UTAV-NNIC1 XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-NHIC1 XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-RNIC1 XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-RHIC1 XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-MNIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-MHIC1 XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-FNIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX-UTAV-FHIC1 XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V. XNX-UTSV-NNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-NHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-RNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-RHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-MNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-MHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-FNIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V. XNX-UTSV-FHIC1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. 1.2. SPARE MPD SENSORS MPD: Multi-Purpose Detector (mV) - ATEX MPD-AMCB1 XNX MPD ATEX/IEC SENSOR CAT 0-100%LEL MPD-AMIV1 XNX MPD ATEX/IEC SENSOR IR CH4 0-100%LEL MPD-AMIF1 XNX MPD ATEX/IEC SENSOR IR 0-100%LEL MPD-AMIC1 XNX MPD ATEX/IEC SENSOR IR CO2 0-5%VV MPD: Multi-Purpose Detector (mV) - UL/CSA MPD-UTCB1 XNX MPD UL/CSA SENSOR CAT 0-100%LEL MPD-UTIV1 XNX MPD UL/CSA SENSOR IR CH4 0-100%LEL MPD-UTIF1 XNX MPD UL/CSA SENSOR IR 0-100%LEL MPD-UTIC1 XNX MPD UL/CSA SENSOR IR CO2 0-5%VV 1.3. SPARE MPD REPLACEABLE CARTRIDGES 1226A0359 XNX MPD CAT CARTRIDGE 0-100%LEL 1226-0300 XNX MPD IR CARTRIDGE 0-100%LEL 1226-0301 XNX MPD IR CARTRIDGE CO2 0-5%VV 1226-0299 XNX MPD IR CARTRIDGE CH4 0-100%LEL 2. XNX Universal Transmitter- for use with Sensepoint HT or 705 HT Flammable Sensor XNX Universal Transmitter excluding Sensepoint High Temp or 705 HT Sensor or remote configurations of MPD. Order required sensor separately from other appropriate section of price list. 2.1. INSTRUMENT XNX Aluminium Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor XNX-AMAV-NNNNN XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX-AMAV-FHNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor XNX Stainless Steel Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor XNX-AMSV-NNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for mV sensors. XNX-AMSV-NHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors. XNX-AMSV-RNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors. XNX-AMSV-RHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors. XNX-AMSV-MNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors. XNX-AMSV-MHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors. XNX-AMSV-FNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors. XNX-AMSV-FHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for mV sensors. XNX Aluminium Transmitter UL/CSA for use with 705 High Temperature Sensor XNX-UTAV-NNNNN XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor XNX-UTAV-FHNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted LM25, configured for 705 High Temperature Sensor XNX Stainless Steel Transmitter UL/CSA for use with model 705 High Temperature Sensor XNX-UTSV-NNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for mV sensors. XNX-UTSV-NHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors. XNX-UTSV-RNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors. XNX-UTSV-RHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors. XNX-UTSV-MNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors. XNX-UTSV-MHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors. XNX-UTSV-FNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors. XNX-UTSV-FHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for mV sensors. 3. XNX Universal Transmitter- for use with XNX Toxic & Oxygen Sensors XNX Universal Transmitter excluding toxic or oxygen sensor. Order required sensor separately from the XNX toxic and oygen sensors section below. 3.1. INSTRUMENT XNX Aluminium Transmitter ATEX/IEC/INMETRO for use with XNX Toxic and Oxygen Sensors XNX-AMAE-NNNNN XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-AMAE-FHNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX Stainless Steel Transmitter ATEX/IEC for use with XNX Toxic and Oxygen Sensors XNX-AMSE-NNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors. XNX-AMSE-NHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for XNX toxic and oxygen sensors. XNX-AMSE-RNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for XNX toxic and oxygen sensors. XNX-AMSE-RHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and oxygen sensors. XNX-AMSE-MNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for XNX toxic and oxygen sensors. XNX-AMSE-MHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for XNX toxic and oxygen sensors. XNX-AMSE-FNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for XNX toxic and oxygen sensors. XNX-AMSE-FHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for XNX toxic and oxygen sensors. XNX Aluminium Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors XNX-UTAE-NNNNN XNX Transmitter, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX-UTAE-FHNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors XNX Stainless Steel Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors XNX-UTSE-NNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors. XNX-UTSE-NHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for XNX toxic and oxygen sensors. XNX-UTSE-RNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for XNX toxic and oxygen sensors. XNX-UTSE-RHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and oxygen sensors. XNX-UTSE-MNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for XNX toxic and oxygen sensors. XNX-UTSE-MHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for XNX toxic and oxygen sensors. XNX-UTSE-FNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for XNX toxic and oxygen sensors. XNX-UTSE-FHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for XNX toxic and oxygen sensors. 3.2. XNX TOXIC AND OXYGEN CARTRIDGES With SENSORS A range of toxic and oxygen sensors for use with the XNX transmitter. Sensors have replaceable cartridges. XNXXSO1SS XNX sensor Oxygen 0-25%VOL XNXXSC1SS XNX sensor Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm) XNXXSH3SS XNX sensor Hydrogen Sulfide 0-15ppm XNXXSH1SS XNX sensor Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm) XNXXSH2SS XNX sensor Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm) XNXXSL1SS XNX sensor Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm) XNXXSL2SS XNX sensor Chlorine Low Range, 0-5.00ppm XNXXSS1SS XNX sensor Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm) XNXXSS2SS XNX sensor Sulfur Dioxide 0-50.0ppm (20.0 to 50.0ppm, 10.0ppm) XNXXSX1SS XNX sensor Chlorine Dioxide 0-1.00ppm XNXXSM1SS XNX sensor Nitrogen Monoxide 0-100ppm XNXXSN1SS XNX sensor Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm) XNXXSG1SS XNX sensor Hydrogen 0-1000ppm XNXXSG2SS XNX sensor Hydrogen 0-10,000ppm XNXXSA1SS XNX sensor Ammonia 0-200ppm (50 to 200ppm, 50ppm) XNXXSA2SS XNX sensor Ammonia 0-1000ppm (200 to 1000ppm, 50ppm) XNXXSR1SS XNX sensor Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm) XNXXSF1SS XNX sensor Hydrogen Fluoride 0-12.0ppm XNXXSP1SS XNX sensor Phosphine 0-1.2ppm XNXXSY1SS XNX sensor Hydrogen Cyanide 0-30.0ppm (Fixed Scale) XNXXSU1SS XNX sensor Fluorine 4 ppm XNXXSE1SS XNX Cartridge, Ethylene Oxide (ETO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm) 3.3. XNX REPLACEMENT TOXIC AND OXYGEN SENSOR Cell Replacement toxic and oxygen sensor cell for use in the XNX toxic and oxygen sensor. XNXO1SS XNX Cartridge Oxygen 0-25%VOL XNXC1SS XNX Cartridge Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm) XNXH3SS XNX Cartridge Hydrogen Sulfide 0-5ppm (1.5 to 5ppm, 0.1ppm) XNXH1SS XNX Cartridge Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm) XNXH2SS XNX Cartridge Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm) XNXL1SS XNX Cartridge Chlorine 0-5.0ppm XNXS1SS XNX Cartridge Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm) XNXX1SS XNX Cartridge Chlorine Dioxide 0-1.00ppm XNXM1SS XNX Cartridge Nitrogen Monoxide 0-100ppm XNXN1SS XNX Cartridge Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm) XNXG1SS XNX Cartridge Hydrogen 0-1000ppm XNXG2SS XNX Cartridge Hydrogen 0-10,000ppm XNXR1SS XNX Cartridge Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm) XNXA1SS XNX Cartridge Ammonia 0-200ppm (50 to 200ppm, 50ppm) XNXA2SS XNX Cartridge Ammonia 0-1000ppm (200 to 1000ppm, 50ppm) XNXF1SS XNX Cartridge Hydrogen Fluoride 0-12.0ppm XNXP1SS XNX Cartridge Phosphine 0-1.2ppm XNXY1SS XNX Cartridge Hydrogen Cyanide 0-30.0ppm (Fixed Scale) XNXE1SS XNX Cartridge Fluorine 4ppm XNXE1SS XNX Cell Kit, Ethylene Oxide (ETO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm) 4. XNX Universal Transmitter- for use with Optima Plus Or Searchline Excel Detectors XNX Transmitter for use with Optima Plus and Searchline Excel IR detectors. Order Optima Plus and Searchline Excel detectors separately from the appropriate section in the price list. Note kit part numbers including standard XNX transmitter configurations have been created for Searchline Excel detectors (see appropriate section in price list). 4.1. INSTRUMENT XNX Aluminuim Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors XNX-AMAI-NNNNN XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX-AMAI-FHNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel XNX Stainless Steel Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors XNX-AMSI-NNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel. XNX-AMSI-NHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for Optima Plus and Searchline Excel. XNX-AMSI-RNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for Optima Plus and Searchline Excel. XNX-AMSI-RHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for Optima Plus and Searchline Excel. XNX-AMSI-MNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for Optima Plus and Searchline Excel. XNX-AMSI-MHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for Optima Plus and Searchline Excel. XNX-AMSI-FNNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for Optima Plus and Searchline Excel. XNX-AMSI-FHNNN XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for Optima Plus and Searchline Excel. XNX Aluminuim Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors XNX-UTAI-NNNNN XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-NHNNN XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-RNNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-RHNNN XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-MNNNN XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-MHNNN XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-FNNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX-UTAI-FHNNN XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel XNX Stainless Steel Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors XNX-UTSI-NNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel. XNX-UTSI-NHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for Optima Plus and Searchline Excel. XNX-UTSI-RNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for Optima Plus and Searchline Excel. XNX-UTSI-RHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for Optima Plus and Searchline Excel. XNX-UTSI-MNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for Optima Plus and Searchline Excel. XNX-UTSI-MHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for Optima Plus and Searchline Excel. XNX-UTSI-FNNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for Optima Plus and Searchline Excel. XNX-UTSI-FHNNN XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for Optima Plus and Searchline Excel. 5. Searchline Excel kits with XNX Transmitters Searchline Excel kits including standard XNX transmitter configured with HART® over 4-20mA output and local HART® port. For Searchline Excel kits including other XNX transmitter configurations contact Honeywell Analytics. 5.1. INSTRUMENT Searchline Excel kits including standard XNX transmitter with HART® over 4-20mA outputs. Searchline Excel Short Range 5m – 40m (15ft - 130ft) 02104-N-XSAA Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB. 02104-N-XSSA Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port JB 02104-N-XSAU Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. 02104-N-XSSU Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. 02104-N-XSAC Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. 02104-N-XSSC Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. 02104-N-NSNA Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, SS316 mounting plates and fitting for XNX. Add XNX and Junction box as required Searchline Excel Medium Range 20m – 120m 02104-N-XMAA Medium range system 20m to 120m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB 02104-N-XMSA Medium range system 20m to 120m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port and JB 02104-N-XMAU Medium range system 20m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. 02104-N-XMSU Medium range system 20m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. 02104-N-XMAC Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. 02104-N-XMSC Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. 02104-N-NMNA Excel line-of-sight gas detection system (without XNX, please order required XNX separately), medium range (40 to 120m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperately. Searchline Excel Long Range 20m – 200m 02104-N-XLAA Long range system 20m to 200m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB 02104-N-XLSA Long range system 20m to 200m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port JB 02104-N-XLAU Long range system 20m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. 02104-N-XLSU Long range system 20m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. 02104-N-XLAC Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. 02104-N-XLSC Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. 02104-N-NLNA Excel line-of-sight gas detection system (without XNX, please order required XNX separately), long range (120 to 200m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperately. 5.2. XNX and Searchline Excel Alignment Kits 02104-N-4006X Short Range Excel & XNX alignment and conformity kit including telescope, carry case and test filters (no SHC1) 02104-N-4007X Long/Medium Range Excel & XNX alignment and conformity kit including telescope, carry case and test filters (no SHC1) 6. XNX Universal Transmitter Accessories and Spare Parts 6.1. XNX ACCESSORIES & SPARES 1226A0358 Pipe Mount Kit 1226A0355 Ceiling Mount Bracket Kit S3KDMK Duct mounting kit for Series 3000 and XNX EC toxic sensors 1226A0382 MPD Interface Adaptor (for use with S3KDMK Duct Mount Kit) 1226A0411 Calibration Gas Flow Adaptor (for use with MPD) S3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors S3KRMK Remote mounting kit for Series 3000 and XNX EC toxic sensors 02000-A-1645 Flow Housing Assembly (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) 00780-A-0035 Flow Housing (full stainless steel, for high temp applications) S3KWP Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic sensors SPXCDWP Standard Weather Protection, uses for ECC toxic sensor cartridges in outdoor 02000-A-1640 Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) 02000-A-1635 Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) 02000-A-1642 Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) SPXCDCC Collecting cone for use with lighter than air gases 2441-0022 UL/CSA Aluminium Junction Box Assembly (for remote mount of MPD sensors) 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved MCT404-XA-02-00 Honeywell HART Communicator for use with XNX Range and Optima Plus gas detectors, Intrinsically-safe, with FM Class I, Div 1/Zone 1, ATEX and IECEx Zone 1 approvals. Including rechargeable battery, mains powered charger and docking station 50079567-011 Leather carrying case for MCT404 (Stylus & shoulder strap included) 10000-A-0004 SS316 Mounting Plate for 2" to 2.5" pipe mounting (Sourced from HAAP Singapore) 10000-A-0054 XNX Transmitter Sunshade (Sourced from HAAP Singapore) 10000-A-0190 2” Pipe mount “V” bracket, M10, including washers & nuts, SS316 (Sourced from HAAP Singapore) XNX-FLOW SS316 Flow Housing for ECC Sensors - for Aspirated Sampling Systems (Sourced from HAAP Singapore) 1226A0354 Remote Gassing Kit 1226-0257 M25 Stopping Plug w/ protective cap and O-ring 1226-0258 3/4" NPT Stopping Plug w/ protective cap and O-ring 0235-0238 Replacement O-ring for XNX front cover 1226A0302 Terminal Block Assembly 6-Pin for XNX EC 1226A0304 Terminal Block Assembly 9-Pin for XNX mV 1226A0305 IR Terminal Block Assembly Kit includes: 9-Pin & 1226A0306 Relay Terminal Block Assembly Kit includes: 9-Pin and 2-Pin blocks 1226A0307 Terminal Block Assembly 10-Pin for XNX Modbus 1226-9001 XNX Transmitter Spare Pod, Infrared Personality, No Options 1226-9002 XNX Transmitter Spare Pod, Infrared Personality, Relay Option 1226-9003 XNX Transmitter Spare Pod, Infrared Personality, ModBus Options 1226-9004 XNX Transmitter Spare Pod, Infrared Personality, Foundation Fieldbus Options 1226-9009 XNX Transmitter Spare Pod, Millivolt Personality, No Options 1226-9010 XNX Transmitter Spare Pod, Millivolt Personality, Relay Option 1226-9011 XNX Transmitter Spare Pod, Millivolt Personality, ModBus Option 1226-9012 XNX Transmitter Spare Pod, Millivolt Personality, Foundation Fieldbus Options 1226-9005 XNX Transmitter Spare Pod, Electrochemical Personality, No Options 1226-9006 XNX Transmitter Spare Pod, Electrochemical Personality, Relay Option 1226-9007 XNX Transmitter Spare Pod, Electrochemical Personality, ModBus Option 1226-9008 XNX Transmitter Spare Pod, Electrochemical Personality, Foundation Fieldbus Options XNX-RLY Relay Option XNX-MB ModBus Option XNX-FFB Foundation Fieldbus Option SPXNXSERVK XNX Service Kit, Including Replacement O-ring for XNX front cover, I.S. modules screws (2 pieces), Earth screw and bracket (3 pieces), O-ring for MPD housing, MPD Sinter O-ring, MPD Sinter locking screw (set screw), ECC sensor - 3 off O-rings, ECC Sensor Lid O-ring, ECC sensor lid - locking screw (set screw) SPXNXTOOLK XNS Tool Kit, Including Magnetic Wand/Screwdriver, Small Screwdriver (for use with Relay board and IR personality board), HEX L-KEY 2.0MM, HEX-L-KEY 1.5MM X 3.06"L 公司依托国内外一批成熟大客户:中海油渤海钻井平台,山东瑞星化工,河北沙河电厂,PAKISTAN NATIONAL REFINERY LIMITED,Petro Oil Supply SDN BHD,THUSO MOLOSIWA BOTSWANA POWER CORPORATION,巴西PAMPA1X345MW燃煤电站等,拥有一批非常优势的品牌资源. 主营:Honeywell霍尼韦尔气体探测,Micro Motion艾默生高准质量流量计,罗斯蒙特变送器,霍尼韦尔控制系统与集成,燃烧控制产品,环境自控,阀门执行器、开关等。 #上海宛畅实业有限公司#专业销售欧美日韩进口的工控产品、仪器仪表等工控备件! 原装进口、型号全、价格优,欢迎询价! 联系电话:021-37824198 / 17740803693 QQ:1093845670/1016549297 专业为您选型。 官网:http://www.parts4automation.com/cn
Part No. Key
上海宛畅实业有限公司是一家自动化设备及工业零部件的专业供应商.公司成立于2012年,专注于为石油,化工,电力,钢铁,制药,环保等领域终端用户提供工程配套自动化设备及工控备件.
2 Pin blocks
在线询盘/留言 请仔细填写准确及时的联系到你